Pages

Showing posts with label news. Show all posts
Showing posts with label news. Show all posts

"Want to play a game?" [How to Survive an Escape Room]

AP Photo

The energy in the room was suddenly heightened as smoke began to slowly filter through the from some other, outside and unknown, location. How could they escape? The puzzles and riddles didn’t make sense, the clues weren’t coming together, the tumblers weren’t tumbling in the locks.   They were still trapped. With the additional stress of a real (or perceived?) emergency, clear heads became foggy, and chances of escape diminished to nearly zero. As their eyes met, the girls were suddenly and simultaneously gripped by the terror of the realization that this was going to be there permanent grave and final resting place.

The room seemed to be a perfect square or cube, considering the ceiling and floor.  The walls were the drab brown of wood paneling made even darker and dingier by the countless fingers and hand prints from others that had come before. It looked like an old office or library, maybe a study.  A bookshelf along one wall, an antique roll-top secretaries desk on the other. Loosely mounted on the wall to her back was a nearly wall-sized, sepia toned, map of the world. On the floor in the center of the room was a large round rug, probably Persian or Oriental. They didn’t know. The rug was a plush woven pattern of small star-type shapes, sewn within larger star-type shapes. Neatly positioned on the rug, was a brown leather chair. The leather was worn and scratched. A few miniature tears permitted the protrusion of wisps of cotton from the seat, back, and arms. Next to the chair, plugged directly into an outlet on the floor, was a tall slender lamp.  The lamp was a brushed bronze, with a single bulb. The bulb was surrounded by a tassled cloth lampshade. The yellow hues cast by the dark shade, added to the already low visibility within the room. Of all the rooms features and decor, the most ominous was the illuminated wall clock. The clock had been counting down. Now, as smoke filled the room, the clock had stopped at 00:28. Twenty-eight minutes until, what? How did they get here? How did they end up in this locked room? Where was the way out?

This could be the start of another film in the Saw franchise. Or, it could be the beginning of locked-room, pulp fiction mystery of the early 1900’s.  For Julia, Amelia, Gosia, Karolina, and Wiktoria, however, this is no work of fiction, instead, it was the final activity of their young lives. The five girls from Koszalin, a city in northern Poland, were celebrating the birthday at an “escape room” game attraction. What should have been a joyous and momentous occasion, a birthday party for a fifteen year-old, ended in tragedy.

A fire investigation determined that the cause of the fire was a gas leak in the heating system. Local fire authorities also noted the presence of faulty, non-compliant electrical wiring co-mingled with flammable materials. The fire started in the lobby or one of the other rooms of the establishment, and smoke filled into the girls locked escape room. One employee was taken to the hospital in serious condition from direct burns to his body. One report states that the firefighter had significant difficult entering the building to extinguish the fire and recover the girls. This is consistent with statements that the injured employee had tried to get to the escape room but could not due to fire damage.

The girls cause of death was ruled carbon monoxide poisoning. Carbon monoxide (CO) is only one half of the “toxic twins” of smoke.  The other is hydrogen cyanide (HCN). The danger of hydrogen cyanide lies in the fact that it can immediately start to attack and kill the organs, in a fire and smoke scenario this danger is further enhanced by the presence of carbon monoxide. As the HCN attacks the organs, the CO is depriving the oxygen from those same organs. The common materials that are used in the makeup of our homes, businesses, clothing and automobiles - plastics, resins, nylon, polyurethane, melamine, acrylonitrile - produce very high levels of CO and HCN when burning.  These chemicals result in the slow painful death of asphyxiation and bodily organ shut-down.

Originating in Japan, but popularized within just the last few years, escape rooms allow small groups of people to work together using clues, riddles, teamwork, and communication to escape an enclosed space. Typically these rooms are themed, and involve competition with groups in other rooms. The clues are comprised of various combinations of puzzles, props, and riddles.

The thirst for adventure, an adrenaline rush, and an emotion filled social experience has contributed to the growing trend of escape room attractions In the United States.  There is an estimated 2,300 escape room facilities in the US. This is up from only twenty-two in 2014. Bringing in nearly $125,000 a year per room, this is a business that will continue to grow.  How can we prevent the ingredients of escape rooms (and nightmares) - locked in a windowless room, imminent danger, no way of escape - from becoming disaster and tragedy?

One tool we can use is building and fire codes and standards. In the United States there are two primary code-making bodies, the International Code Council (ICC), and the National Fire Protection Association (NFPA). Each of these organizations publish multiple codes and standards including a building code and a fire code.  The ICC publishes the International Building Code (IBC), and the International Fire Code (IFC). The NFPA publishes NFPA 5000, Building Construction and Safety Code; NFPA 1, Fire Code; NFPA 101, Life Safety Code.

Utilization of these codes and standards for building construction, fire protection, or life safety is not mandated or required.  However, all fifty states do voluntarily adopt some version of these, or have created their own codes and standards based on their content.  Once adopted by the state, the provisions then become enforceable as law. Currently neither of these code bodies publishes a code or standard specific to “escape rooms”. They do have sections in their codes for “special amusement buildings”.  This is the section of code that is typically applied to these structures. Escape rooms and special amusements fall into the general building classification of an “assembly occupancy”.

The National Fire Protection Association defines an assembly occupancy as, “an occupancy (1) used for a gathering of 50 or more persons for deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation, or similar uses; or (2) used as a special amusement building, regardless of occupant load.”

Similarly, the International Code Council defines an assembly occupancy as an occupancy that “includes, among others, the use of a building or structure, or a portion thereof, for the gathering of persons for purposes such as civic, social or religious functions; recreation, food or drink consumption or awaiting transportation…”

A thorough review and application of these codes and standards generates the following mash-up of requirements.

Automatic Fire Sprinkler Systems.
A fire sprinkler system is required for the protection of these structures. Both code bodies allow the omission of fire sprinklers for amusements and attractions that are less than 1,000 sq.ft. and when the travel distance to an exit is less than 50 feet. If the space is less than 10 feet high and 160 feet wide, then sprinklers may also be omitted.

Smoke and Fire Detection.
Smoke alarms and other fire detection devices are required to be installed throughout the amusement space.

Fire Alarm System.
The smoke and fire detection devices are required to send any activation signals to a constantly monitored location.  Additionally, the system must be equipped with an emergency voice/communication system that can be clearly heard throughout the facility. If the fire alarm or fire sprinkler is activated, lighting should be activated so that the exits and exit pathways are clearly illuminated.  Any other sounds or visual application that may be confusing or conflicting are required to be terminated.

Exit Markings.
Exit signage is required to show the location of exit doors and pathways. Directional markings are also required, but they can be setup to be visible only in the event of an alarm or fire sprinkler activation.  Floor proximity exit signage is required and must be mounted with the bottom of the sign between 6” and 18” above the floor. The IBC states that the bottom of the sign must be no more than 8” above the floor. If the exit sign denotes the location of a door, the sign must be within 4” of the door frame.

Interior Finish.
Interior finish includes paints, fabrics, carpets, and other items that are applied to the walls, floors, or ceilings of a structure. These products are classified based on flame spread and smoke development. Class A is the most flame resistant, with a flame spread index of 0-25 and a smoke developed index of 0-450, and is the rating required for special amusement structures.

Another tool that can be utilized for the protection of occupants within escape rooms is to follow industry best practices. The primary best practice is to have a sufficient number of personnel, that are properly trained, to staff the escape room attraction. The staff must be knowledgeable of emergency procedures, fire alarm response, safe exiting and emergency egress procedures, and proper operations of the escape room components and access ways.  Staff should provide instructions on emergency procedures and exit locations to participants prior to the start of the event. Staff should monitoring the rooms via live video feeds. This allows for prompt notification of issues or injuries, and can also be an effective method of communication with participants, if needed.

In construction of the room itself, it is recommended that they have a simple progression and avoid many twists, turns, or small passageways. This contributes to a more quick and direct  exit access in case of emergency. Utilizing only low-voltage electronics for room equipment and props can minimize any potential fire hazard.

It is always a good practice for escape room owners and managers to maintain clear and open communication with the local fire department.  Regular inspections of fire protection and life safety equipment, and the space as a whole, should be encouraged and conducted.

Don’t let the fun, excitement, and faux-adventure of the special amusement of an  “escape room” become a tragedy. Before starting the game ensure that you know where the exits are, you know how to get out of the building, and you know how to notify staff of any issue that may arise.  

John Denley, whose company Escape Room International designs and builds escape rooms across the country, tells owners this, “In order to stay in business, you have to stay up with safety standards, and you have to play by the book. It helps everyone sleep better at night...You want to go into a place with as much safety as possible because you also want to know your investment is safe.”

The man who ran the escape room that killed Julia, Amelia, Gosia, Karolina, and Wiktoria has lost his livelihood and his standing in the community. He is facing up to eight years in prison for “intentionally creating a fire danger and unintentionally causing the deaths.”  At the girls’ funeral, Rev. Wojciech Pawlak eulogized, “In their friendship they were and will remain together. They were together when their lives were ending, they are together here and they will rest together in the cemetery. Forever…”

National Museum of Brazil Fire [Why We Do This Job]


On the evening of September 3, 2018, the National Museum of Brazil was gutted by fire. This 200 year old institution, a former palace for the Portuguese royal family, housed more than 20-million items and artifacts. Ninety percent of these items have been lost. These items represent a past that no longer exists for Brazil, languages that are no longer spoken, skeletal remains of the earliest living humans, and 200 years of research and collected knowledge.

This tragic loss serves as a poignant reminder for the reason why we, fire prevention, protection, and life safety professionals, do this job everyday. And the importance of our role in preventing these tragedies within our communities.

Several years ago the United States Fire Administration published a document that outlined the five impacts of fire. The premise of the document was that no fire is ever “just a fire”. Fire loss, of any size, has the potential to affect the community and the organization in five distinct ways: economically, organizationally, legally, psychologically, and politically.  As the news stories and editorial pieces continue to come out on the National Museum fire, we can clearly see how these five impacts of fire are affecting the local community, the people of Brazil, and International interests.

This is evident in the headlines and stories that include the following quotes:

“...our tangible record of life on earth…”
“...destruction of careers…”
“...negligence…”
“...a crime…”
“...mismanagement…”
“...systemic neglect of cultural institutions…”

Records and reports dating back to the 1950’s show a pattern of fire protection and life safety neglect. Recent citizen complaints identified the specific hazards of flammable plastic roofing material and exposed and jury-rigged electrical wiring. Additionally, other reports state “beyond a few fire extinguishers and smoke detectors, the museum did not have a fire suppression system.”

Preliminary reports have identified the cause of the fire as originating from a paper balloon lantern or an electrical short circuit in one of the museum’s lab areas.  However, there are three core reasons, at the highest government levels, that allowed this preventable loss to happen:
  • Tight budgets and availability of funds
  • Mismanagement of money and resources
  • Neglect and lack of prioritization 
These three dangerous actions and mindsets are not unique to Brazil, but are common throughout many communities. Beyond our responsibilities related to code compliance, plan review, and fire inspections, as fire protection professionals we also have a great responsibility to mold and change mindsets of our community leaders and citizens. We must constantly work to keep investments in  fire protection and life safety at the forefront, and consistently reiterate the life altering effect and impacts that lack of these essential services and systems will lead to.

Related Resources:



From Mall to Mega-Church

With the downturn of the economy and the exit of big-box retailers such as Sears and K-mart, an increasing trend is to turn these former shopping spaces into houses of worship. Making headlines locally (South Florida), is Christ Fellowship, which is creating a fifth campus in a vacated Dillard’s store . A current campus in Royal Palm is a former Target store. Perhaps, you have one of these moving into your jurisdiction, or maybe you're a pastor contemplating the future take over of your local Best Buy. In either case, here are a few things to consider.
No doubt, it takes much work to turn a mercantile occupancy (used for the display and sale of merchandise) into a place of assembly (used for a gathering of 50 or more persons for deliberation, worship, entertainment, etc.). The National Fire Protection Association, Life Safety Code (NFPA 101) states that when a building changes occupancy type (from mercantile to assembly) the space must meet the existing fire/life safety codes for the newly created occupancy (existing assembly), however, the fire alarm, automatic sprinkler, and communications systems must meet the requirements for new construction. (101:43.7.2.1)

One of the first things to consider before delving into the fire code is total occupant load. Typically, a house of worship will have fixed seating making the actual occupant load the total number of seats (to be shown on submitted plans). However, without fixed seating the calculation will be based on a less concentrated use, which allows for 15 sq.ft. per person. (101:7.3.1.2) These former shopping centers can easily exceed 100,000 sq.ft. (the aforementioned Dillard’s is 127,000 sq.ft.). Based on this calculation (without fixed seating), the allowed occupant load would be more than 6,500 occupants. This easily exceeds the system requirements that come into effect for occupant loads of over 300, and also requires a minimum separation between the assembly and mall area of 2 hours. (101:6.1.4.4.1)

The system requirements for new assembly occupancies include:
  • Full fire alarm system with voice communication/evacuation. (101:12.3.4.1) 
  • Automatic fire sprinkler system. (101:12.3.5.2) 
Mercantile occupancies of this size should already be equipped with fire alarm and sprinkler protection.

Every church has a stage (in church terms, a “platform”). The stage shall meet the requirements of NFPA 101:13.5, which include: 
  • Inclusion of a proscenium curtain (a curtain separating the stage from the auditorium). 
  • Stages over 1,000 sq.ft. shall be equipped with standpipes for fire fighting. 
  • Fire sprinklers are required, including under the stage area (see exceptions in 101:13.4.5.10.3). 
In addition to spiritual feeding churches are providing physical feeding, by way of in-house restaurants and cafes’. (101:13.7.2) 
  • Cooking equipment is required to be protected by a hood and suppression system. 
  • Candles and flaming dishes are to be properly protected and approved by the local fire authority. 
  • LP gas appliances are to be listed and installed per applicable codes (NFPA 58). 
Open flames and pyrotechnics are prohibited from use in all assembly occupancies except for ceremonial or religious purposes. The local fire authority should be consulted prior to use, and every precaution taken to prevent the ignition of flammable materials. For more information on regulations for the use of pyrotechnics see, NFPA 1126 and NFPA 160. (101:13.7.3)

Trained crowd managers are required at a ratio of 1 per 250 occupants. Assembly occupancies used exclusively for worship with an occupant load of less than 2,000 is exempt from the crowd manager requirement. (101:13.7.6)

Seats in areas accommodating more than 200 persons are to be securely fastened to the floor. In restaurant, and other entertainment areas where permanently fastened seats are not practical unsecured seating is permitted. (101:13.7.9)

Any assembly occupancy with an occupant load greater than 6,000 requires a life safety evaluation. This evaluation shall be performed by a person acceptable to the local fire authority, and is to include an assessment of building systems, features, and management. The evaluation shall contain an in-depth analysis of possible hazards, and emergency response plans. (101:13.4.1)





Related Posts:

Fire Safety Guide to Mardis Gras


Joining the Mardi Gras festivities today? Entering a float into the parade?  Here are a few fire prevention and life safety guidelines that must be followed to ensure that your float is fire safe, and that the lives of the particpants will not be endangered.

The regulations by the Lake Charles Fire Prevention Bureau for float safety that will be enforced include:


  • Maintenance - float and tow vehicle are in good working order.
  • Decorations - all decorative materials used are flame retardant.
  • Vision/Communication - driver has proper 180 degree vision (or spotters) or communication with float riders.
  • Fire Suppression - large floats have at least two five pound ABC fire extinguishers. Small floats have at least one fire extinguisher. 
  • Riders - float riders have sturdy support handrails or other means to prevent falls. Riders shall have secondary means of escape in the event of emergency.
  • Generator - portable generator is securely mounted and separated from combustible materials.
  • Wiring - all electrical wiring must be of the appropriate type to be used and must properly secured.
  • Exits - doors to floats shall remain unlocked at all times while occupied.






Related Posts:
Firefighter jobs in and near Lake Charles, LA:

High Cost of Non-Compliance, "Next Top Model"



Last year, Los Angeles firefighter, Glen Allen was killed when a ceiling fell on top of him, as he was fighting a fire.  The fire was in the 12,000 square foot home of architect Gerhard Becker.  Becker, who designed and oversaw construction of the home, has been charged with involuntary man slaughter due to the faulty installation of an indoor "fire pit" (authorities determined to be the cause of the fire). 


Read about the origin and cause of this fire here: Substandard Construction Blamed for LA Fire Death


Related Posts:

Some headlines you might have missed this week...




Squirrel Sets Off Fire Alarm at Florida School [video]
Indian Hospital Tragedy Shakes Up Administration
DIY Brush Trucks
Improved ISO Rating
Man's Face Catches Fire During Routine Surgery (second of this type of incident in one week)
$12,000,000 Market Invests in Fire Protection




Don't forget to come back everyday for the firefighters gift guide, featuring a different item each day!

Left to Die



Early this morning, a fire broke out in a hospital in India.  The hospital staff abandoned the patients and fled.

Read the full story here --> http://news.yahoo.com/hospital-staff-abandon-patients-fire-73-die-092652490.html

What happened?

Top headlines and stories of interest (that you might have missed) from this past week:


Education Debate - hiring of Florida chief stirs up debate over the necessity of college education


Fire Prevention Week Reading - from the American Red Cross blog, various fire prevention week articles


Commissioner Putnam Encourages Firewise Behavior - Florida Dept. of Agriculture & Consumer Services commemorates National Fire Prevention Week


Stoking the Flames - live video from inside a home training burn


Disney Ride Fire - small fire on Disney ride started by lightbulb


Firefighters Save Their Own - from Bonita Springs




How was your fire prevention week?  What special activities did your department take part in?

Martin County Receives Remembering When Award

Every year the National Fire Protection Association (NFPA) selects 40 community/teams to attend its Remembering When conference.  Each team consists of one fire department representative and one senior care agency.  This year Martin County Fire Rescue partnered with the Council on Aging, and is proud to announce that they have been selected for the Remembering When conference award!  On December 4-6, 2011 our team will be heading to Boston to be equipped with educational tools that will prevent falls and fires in older adults.

Remembering When presentation





Annually, Martin County Fire Rescue responds to more than 12,000 medical calls, 53% of these are to people over the age of 65.  We respond to more falls, than to any other type of medical emergency; nearly 2,500 fall responses per year.  These overwhelming statistics demanded a response.  That response has come in the form of the National Fire Protection Association’s , Remembering When: A Fall and Fire Prevention Program for Older Adults.  Partnering with the Council on Aging, and by way of group presentations and home visits,  implementation of this program will enhance the lives of older adults, promote independence, and prevent premature institutionalization.



Remembering When is centered around 16 key safety messages – eight fire preventionand eight fall prevention





  1. If you smoke, smoke outside
  2. Give space heaters space.
  3. Be kitchen wise.
  4. Stop, drop, and roll.
  5. Smoke alarms save lives.
  6. Plan and practice your escape from fire.
  7. Know your local emergency number.
  8. Plan your escape around your abilities.
  9. Exercise regularly.
  10. Take your time.
  11. Clear the way.
  12. Look out for yourself.
  13. Wipe up spilled liquids immediately.
  14. Be aware of uneven surfaces.
  15. Tread carefully.
  16. Put your best foot forward.